ZAIDI, Syed Haseeb Haider, SHENFIELD, Alex, ZHANG, Hongwei and IKPEHAI, Augustine (2026). Self-Supervised CNN–Transformer Anomaly Detection for Bearing Health Monitoring. Processes, 14 (15): 2452. [Article]
Documents
37786:1351269
PDF
processes-14-02452.pdf - Published Version
Available under License Creative Commons Attribution.
processes-14-02452.pdf - Published Version
Available under License Creative Commons Attribution.
Download (4MB) | Preview
Abstract
Reliable bearing fault detection is essential for predictive maintenance in industrial systems; however, obtaining labelled fault data is often expensive, time-consuming, and impractical in real-world deployments. To address this challenge, this study proposes a healthy-only self-supervised anomaly detection framework for bearing health monitoring using vibration measurements. The proposed approach combines convolutional neural networks and Transformer-based temporal modelling to learn informative representations from healthy vibration signals without requiring fault labels during representation learning. Three self-supervised learning strategies—reconstruction-based, contrastive, and a unified contrastive–reconstruction objective—are investigated to evaluate the effectiveness of different representation learning approaches. The learned latent representations are subsequently analysed using Isolation Forest and Mahalanobis-distance anomaly scoring methods. To provide a realistic assessment of generalisation, a strict grouped cross-validation protocol is employed, where data are partitioned at the sample level to prevent information leakage between training and testing sets. Furthermore, prevalence-aware experiments are conducted under 5% and 10% fault prevalence scenarios to assess deployment robustness. Experimental results on the Paderborn bearing dataset demonstrate that the proposed CNN + Transformer model trained with combined contrastive and reconstruction objectives and evaluated using Isolation Forest achieves the best overall performance, obtaining a ROC-AUC of 0.878±0.015
, a PR-AUC of 0.958±0.005
, and an F1-score of 0.590±0.040
. The results consistently outperform classical feature-based approaches, One-Class SVM, and autoencoder baselines. Ablation analysis further shows that combining contrastive and reconstruction objectives produces more informative representations than either objective alone. The findings demonstrate that the proposed healthy-only self-supervised framework provides an effective and label-efficient approach for rolling bearing anomaly detection and shows promise for predictive maintenance applications where labelled fault data are limited or unavailable.
More Information
Statistics
Downloads
Downloads per month over past year
Metrics
Altmetric Badge
Dimensions Badge
Share
Actions (login required)
![]() |
View Item |


Tools
Tools