A new approach towards performing plasma nitriding of CrCoMo medical grade alloys using HIPIMS discharge

SHUKLA, Krishnanand, PURANDARE, Yashodhan, SUGUMARAN, Arunprabhu, LOCH, Daniel, EHIASARIAN, Arutiun, KHAN, Imran and HOVSEPIAN, Papken (2021). A new approach towards performing plasma nitriding of CrCoMo medical grade alloys using HIPIMS discharge. 64th Annual Technical Conference Proceedings. [Article]

Documents
30097:602894
[thumbnail of A New Approch towards plasma nitriding using HIPIMS-SVC-Elements.pdf]
PDF
A New Approch towards plasma nitriding using HIPIMS-SVC-Elements.pdf - Accepted Version
Restricted to Repository staff only
Available under License All rights reserved.

Download (1MB)
Abstract
CoCrMo alloy, although an acceptable choice for metal-on-metal prosthetic implants, requires enhancement of its mechanical and tribological properties. In this work, HIPIMS discharge was utilised to perform a low-pressure plasma nitriding (HLPN) process. XRD studies revealed the formation of a compound layer consisting of a desirable mixture of Co2-3N and Co4N phases and a (111):(200) [43:57] texture. The process led to a higher rate of nitrogen diffusion, (case depth of 2.5µm in 4 hours) than that observed for a conventional dc plasma nitriding process (DCPN) (2.1µm in 18 hours). The HLPN treatment resulted in a higher hardness of 23 GPa as compared to 20 GPa achieved for DCPN and substantially higher than that measured for the bare alloy (7.9GPa). Consequently, a significant improvement in dry sliding wear resistance (KC=1.18×10-15m3N-1m-1) and lower friction coefficient (µ=0.6) was achieved as compared to the untreated specimens ((KC=6.0×10-14m3N-1m-1) and µ=0.8). The defined H/E and H3/E2 values of 0.078 and 0.135 respectively indicated that the HLPN process enhances toughness. Potentiodynamic polarisation tests in Hank’s solution showed a significant improvement in corrosion resistance; ECorr value of -218mV was considerably nobler compared to the untreated alloy (ECorr=-775 mV) whereas corrosion current densities of ICorr= 5×10-5 mAcm-2 were found to be two orders of magnitude lower as compared to the untreated CoCrMo alloy with ICorr= 2 analysis revealed that the plasma nitrided layers present a reliable barrier against Me-ion release from CoCrMo alloy. Enhancement of mechanical and corrosion properties and favorable Me-ion release performance combined with the significant reduction in process time makes HLPN a powerful technique for surface treatment of medical grade CoCrMo alloys.
More Information
Metrics

Altmetric Badge

Dimensions Badge

Share
Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email

Actions (login required)

View Item View Item