TILLER, Nicholas, TURNER, Louise, HART, John and CASABURI, Richard (2020). Airflow dynamics and exhaled-breath temperature following cold-water ingestion. Respiratory Physiology & Neurobiology, 284, p. 103564. [Article]
Documents
27424:559385
PDF
Airflow dynamics and exhaled breath temperature following cold water ingestion.pdf - Accepted Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.
Airflow dynamics and exhaled breath temperature following cold water ingestion.pdf - Accepted Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.
Download (322kB) | Preview
Abstract
Introduction. Drinking cold water evokes decreases in spirometric indices of lung function. We studied whether this could be explained by changes in exhaled-breath temperature (EBT), airflow dynamics,and spirometer measurement sensitivity. Methods. In a randomized/crossover design, 10 healthy adults
consumed 1,000 mL refrigerated water (2.1±0.64 ºC) or water at room temperature (19.4±0.5 ºC), with
EBT assessed at baseline and at 5,10,15 and 30-min post-ingestion. The influence of EBT on pneumotachograph measurement characteristics was modelled using computational fluid dynamics
(CFD). Results. At 5-min post-ingestion, EBT was lower (p<0.001) following the ingestion of cold
water versus water at room-temperature (31.7±1.1 vs. 33.0±0.9 °C), and remained lower until 30-min
post-ingestion. At a flow of 8 L*s−1
, a decrease in EBT of 2.1 ° 29 C (observed following cold-water ingestion) was modelled to underpredict lung volume by 0.7%. Conclusions. Cold water reduces EBT
below baseline but effects pneumotachograph measurements only negligibly; thus, decreased lung
function following cold-water ingestion likely has a physiological explanation which warrants further
study
More Information
Statistics
Downloads
Downloads per month over past year
Metrics
Altmetric Badge
Dimensions Badge
Share
Actions (login required)
View Item |