Assessment of a Microsoft Kinect-based 3D scanning system for taking body segment girth measurements : a comparison to ISAK and ISO standards

CLARKSON, Sean, WHEAT, Jonathan, HELLER, Ben and CHOPPIN, Simon (2015). Assessment of a Microsoft Kinect-based 3D scanning system for taking body segment girth measurements : a comparison to ISAK and ISO standards. Journal of Sports Sciences, 34 (11), 1006-1014. [Article]

Documents
11138:34182
[thumbnail of Clarkson Assessment of a Microsoft Kinect-based 3D scanning system.pdf]
Preview
PDF
Clarkson Assessment of a Microsoft Kinect-based 3D scanning system.pdf - Accepted Version
Available under License All rights reserved.

Download (584kB) | Preview
11138:34226
[thumbnail of Clarkson Microsoft Kinect-based 3D scanning system figures.zip]
Archive (ZIP)
Clarkson Microsoft Kinect-based 3D scanning system figures.zip - Accepted Version
Available under License All rights reserved.

Download (12MB)
11138:34183
[thumbnail of Clarkson 11138.pdf]
PDF
Clarkson 11138.pdf
Restricted to Repository staff only

Download (52kB)
Abstract
Use of anthropometric data to infer sporting performance is increasing in popularity, particularly within elite sport programmes. Measurement typically follows standards set by the International Society for the Advancement of Kinanthropometry (ISAK). However, such techniques are time consuming, which reduces their practicality. Schranz et al. recently suggested 3D body scanners could replace current measurement techniques; however, current systems are costly. Recent interest in natural user interaction has led to a range of low-cost depth cameras capable of producing 3D body scans, from which anthropometrics can be calculated. A scanning system comprising 4 depth cameras was used to scan 4 cylinders, representative of the body segments. Girth measurements were calculated from the 3D scans and compared to gold standard measurements. Requirements of a Level 1 ISAK practitioner were met in all 4 cylinders, and ISO standards for scan-derived girth measurements were met in the 2 larger cylinders only. A fixed measurement bias was identified that could be corrected with a simple offset factor. Further work is required to determine comparable performance across a wider range of measurements performed upon living participants. Nevertheless, findings of the study suggest such a system offers many advantages over current techniques, having a range of potential applications